This is NA61/SHINE electronic logbook (read-only BACKUP!)

Run summary Shift logbook Run settings Beam logbook BPD logbook DAQ logbook DCS logbook Experts logbook Gas logbook TOF logbook Trigger logbook PSD logbook VD logbook Run coordination Detector Upgrade DRS logbook
    NA61/SHINE logo
Message ID: 6     Entry time: Thu, 1.10.2015 08:47:20
Author: S.Pulawski 
Subject: 2015 Basic settings for Ar+Sc @ 75 AGeV  
Beamline settings:
Beam file on beam computer

Beam counter positions (rack number 17, top panels):
V1 75.4 mm
V0 1.5 mm (out of beam, while the nominal beam position is 55.6 mm)
S2 86.1 mm
S5 horizontal: -67.9 mm; vertical: 13.8 mm

Beam momentum: 75.00 AGeV/c ( GeV/c proton equivalent)


Trigger file in use: 2015_Ar_75AGeV.cnf

Trigger settings:
T1=S1*S2*V1bar
T2=S1*S2*V1bar*S5bar*PSDbar
T3=S1*S2
T4=S1*S2*V1bar*S5bar

Trigger scaler factors:
T1 =
T2 = 1
T3 =
T4 =

HV settings:
https://na61-elog.cern.ch/Experts+logbook/245

Thresholds:

PSD: -325 mV
S5: -0.753 V
S2: -0.45 V
S1: -0.50 V

Magnets:
VTX1 A (set), (measured)
VTX2 A (set), (measured)

Geometry of S counter like in Ar+Sc@13A GeV/c
PSD with 10cm brass degrader in front. Beam hit PSD in geometrical center.
Trigger 16 small PSD modules.
ELOG V3.1.3-7933898