Message ID: 267     Entry time: Mon, 5.09.2016 12:25:33
Author: A.Aduszkiewicz 
Subject: VTPC-2 sector 2 amp meter 
VTPC-2 sector 2 current meter appears to be broken.

We tried to apply 100V to the chamber. Power supply tripped.
We tried two other channels at the power supply - still tripping.
We disconnected the TPC cable from the current meter, and the power supply was still tripping.
Finally we disconnected a cable connecting the power supply to the current meter (at the current meter), and then it did not trip.

We have no spares. We need to look for a replacement, or a new unit.