| Logbook for all experts' activities |
 |
|
|
Message ID: 263
Entry time: Sat, 2.07.2016 14:08:19
|
| Author: |
A.Aduszkiewicz, M. Kuich |
| Subject: |
TPC HV status |
|
|
amplification voltage/drift voltage
|
| VTPC-1 | VTPC-2 | MTPC-L | MTPC-R | GAP TPC | | | |
2/07/2016 14:05 | 0V/13kV | 0V/13kV | 0V/19kV | 0V/19kV | 0V/10.2kV | | (AA) | |
3/07/2016 19:31 | 0V/13kV | 0V/13kV | 0V/19kV | 0V/19kV | 0V/10.2kV | Potential strips ON | (MK) | |
4/07/2016 15:31 | 100V/13kV | 100V/13kV | 100V/19kV | 100V/19kV | 100V/10.2kV | | (MK) | |
4/07/2016 18:23 | 300V/13kV | 300V/13kV | 300V/19kV | 300V/19kV | 300V/10.2kV | | (MK) | |
5/07/2016 9:35 | 500V/13kV | 500V/13kV | 500V/19kV | 500V/19kV | 500V/10.2kV | | (MK) | |
5/07/2016 9:35 | 600V/13kV | 600V/13kV | 600V/19kV | 600V/19kV | 0V/0kV | GapTPC HV off due to stopped gass flow | (MK) | |
6/07/2016 14:35 | 730V/700V/13kV | 670V/13kV | 670V/600V/19kV | 670V/600V/19kV | 500V/10.2kV | | (MK) | |
6/07/2016 18:50 | 830V/800V/13kV | 770V/13kV | 770V/700V/19kV | 770V/700V/19kV | 600V/10.2kV | | (MK) | |
7/07/2016 10:25 | 880V/850V/13kV | 820V/13kV | 820V/750V/19kV | 820V/750V/19kV | 700V/10.2kV | | (MK) | |
7/07/2016 16:00 | 960V/930V/13kV | 860V/13kV | 860V/790V/19kV | 860V/790V/19kV | 800V/10.2kV | | (MK) | |
8/07/2016 11:30 | 960V/930V/13kV | 860V/13kV | 860V/790V/19kV | 860V/790V/19kV | 0V/10.2kV | GapTPC wire HV off due to reduction of gas flow | (PP) | |
9/07/2016 14:50 | 960V/930V/13kV | 860V/13kV | 860V/790V/19kV | 860V/790V/19kV | 500V/10.2kV | | (PP) | |
9/07/2016 15:20 | 960V/930V/13kV | 860V/13kV | 860V/790V/19kV | 860V/790V/19kV | 550V/10.2kV | | (PP) | |
9/07/2016 16:00 | 1010V/980V/13kV | 910V/13kV | 910V/840V/19kV | 910V/840V/19kV | 600V/10.2kV | | (PP) | |
9/07/2016 17:30 | 1010V/980V/13kV | 910V/13kV | 910V/840V/19kV | 910V/840V/19kV | 650V/10.2kV | | (PP) | |
10/07/2016 09:15 | 1010V/980V/13kV | 910V/13kV | 910V/840V/19kV | 910V/840V/19kV | 700V/10.2kV | | (PP) | |
11/07/2016 16:00 | 1010V/980V/13kV | 910V/13kV | 910V/840V/19kV | 910V/840V/19kV | 750V/10.2kV | | (PP) | |
11/07/2016 18:20 | 1010V/980V/13kV | 910V/13kV | 910V/840V/19kV | 910V/840V/19kV | 950V/10.2kV | GTPC HV up in 50V steps | (PP) | |
11/07/2016 21:15 | 1060V/1030V/13kV | 960V/13kV | 960V/890V/19kV | 960V/890V/19kV | 950V/10.2kV | | (AA) | |
11/07/2016 22:25 | 1110V/1080V/13kV | 1010V/13kV | 1010V/940V/19kV | 1010V/940V/19kV | 1000V/10.2kV | MTPC-L sector 20 left at 960V, due to high current | (AA) | |
11/07/2016 22:45 | 1110V/1080V/13kV | 1010V/13kV | 1010V/940V/19kV | 1010V/940V/19kV | 1000V/10.2kV | MTPC-L sector 20 reduced to 910V, as it was at 20 nA out of spill | (AA) | |
11/07/2016 22:50 | 1160V/1080V/13kV | 1030V/13kV | 1030V/950V/19kV | 1030V/960V/19kV | 1000V/10.2kV | MTPC-L sector 20 at 910V | (AA) | |
11/07/2016 23:20 | 1170V/1100V/13kV | 1040V/13kV | 1040V/970V/19kV | 1040V/970V/19kV | 1050V/10.2kV | MTPC-L sector 20 at 910V | (AA) | |
12/07/2016 0:15 | 1060V/1030V/13kV | 910V/13kV | 910V/840V/19kV | 910V/840V/19kV | 1000V/10.2kV | 150V below the nominal values | (AA) | |
12/07/2016 17:50 | 1110V/1080V/13kV | 960V/13kV | 960V/890V/19kV | 960V/890V/19kV | 1050V/10.2kV | | (AA) | |
12/07/2016 18:15 | 1160V/1130V/13kV | 1010V/13kV | 1010V/940V/19kV | 1010V/940V/19kV | 1100V/10.2kV | MTPC-L sector 20 at 960V (6nA out of spill) | (AA) | |
12/07/2016 18:28 | 1190V/1160V/13kV | 1040V/13kV | 1040V/970V/19kV | 1040V/970V/19kV | 1130V/10.2kV | MTPC-L sector 20 at 960V (6nA out of spill) | (AA) | |
12/07/2016 23:45 | 1060V/1030V/13kV | 910V/13kV | 910V/840V/19kV | 910V/840V/19kV | 1000V/10.2kV | 150V below the nominal values | (AA) | |
13/07/2016 9:40 | 1060V/1030V/13kV | 910V/13kV | 910V/840V/19kV | 910V/840V/19kV | 0V/0kV | GAP TPC HV off for geometrical survey | (AA) | |
13/07/2016 14:30 | 1060V/1030V/13kV | 910V/13kV | 910V/840V/19kV | 910V/840V/19kV | 1000V/10.2kV | GAP TPC HV on after geometrical survey | (MK) | |
13/07/2016 18:35 | 1060V/1030V/13kV | 910V/13kV | 910V/840V/19kV | 910V/840V/19kV | 1100V/10.2kV | | (MK) | |
15/07/2016 9:30 | 1140V/1110V/13kV | 990V/13kV | 990V/920V/19kV | 990V/920V/19kV | 1130V/10.2kV | Ramping up | (MK) | |
15/07/2016 14:00 | 1210V/1180V/13kV | 1060V/13kV | 1060V/990V/19kV | 1060V/990V/19kV | 1150V/10.2kV | Nominal voltages | (MK) | |
20/07/2016 18:50 | 1110V/1080V/13kV | 960V/13kV | 960V/890V/19kV | 960V/890V/19kV | 1050V/10.2kV | -100V on amplification due to beam tunning. | (MK) | |
21/07/2016 19:30 | 1210V/1180V/13kV | 1060V/13kV | 1060V/990V/19kV | 1060V/990V/19kV | 1150V/10.2kV | Nominal voltages | (MK) | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|