This is NA61/SHINE electronic logbook (read-only BACKUP!)

Run summary Shift logbook Run settings Beam logbook BPD logbook DAQ logbook DCS logbook Experts logbook Gas logbook TOF logbook Trigger logbook PSD logbook VD logbook Run coordination Detector Upgrade DRS logbook
  Logbook for beam experts  NA61/SHINE logo
Message ID: 284     Entry time: Sun, 30.11.2025 12:29:47
Author: K. Wojcik 
Subject: Pb 2025 run setup 
Material in counters:
  • S1: quartz, 80 x 80 x 2 mm
  • S2: quartz, 40 x 40 x 2 mm
  • V0: scintillator, 40 x 40 x 5 mm, hole: circle, diameter = 5 mm
  • V1: scintillator, 80 x 80 x 5, hole: circle, diameter = 8 mm.
  • S3: scintillator, width = 15 mm, thickness = 1 mm, length = ~200 mm. It is covered by thin teflon tape, below 0.2 mm in total.

Counter voltages and thresholds
  • S1_1: -1250 V, threshold: 120 mV
  • S1_2: -1400 V, threshold: 120 mV
  • S1_3: -1200 V. threshold: 120 mV
  • S1_4: -1350 V, threshold: 120 mV
  • S2: - 620 V, threshold: 250 mV
  • V0: - 600 V, threshold: 100 mV
  • V1: - 600 V, threshold: 50 mV
  • S3: +1700 V, threshold: 230 mV

Counter positions (relative, displayed on movement controllers)
  • S2: 83.2
  • V0: 86.5
  • V1: 52
  • S3: +6 mm (Jura)
Maximum safe V1 position is 64! Do not exceed this value to avoid hitting the pipe wall with scintillator.

Trigger definitions:
(positive, vetoed)

  • T1 = S1 * S2 * V0 * V1, scaler = 100
  • T2 = T1 * S3, scaler = 1
  • T3 = S1 * S2, scaler = 1000
  • T4 = S3, scalers = 0

Typical count rates:
  • S1
  • L2
  • T2/T1
Attachment 1: v0_scan_30_11_2025.png  243 kB  Uploaded Sun, 30.11.2025 15:05:50  | Hide | Hide all
v0_scan_30_11_2025.png
Attachment 2: v1_scan_30_11_2025.png  219 kB  Uploaded Sun, 30.11.2025 15:39:42  | Hide | Hide all
v1_scan_30_11_2025.png
Attachment 3: V0_scan_2025_12_01_19_30.png  310 kB  Uploaded Mon, 1.12.2025 19:29:48  | Hide | Hide all
V0_scan_2025_12_01_19_30.png
Attachment 4: S3_scan_2025_12_01_20_00.png  362 kB  Uploaded Mon, 1.12.2025 20:01:44  | Hide | Hide all
S3_scan_2025_12_01_20_00.png
Attachment 5: V0_scan_2025_12_02_02_00.png  324 kB  Uploaded Tue, 2.12.2025 01:59:08  | Hide | Hide all
V0_scan_2025_12_02_02_00.png
Attachment 6: CESAR_GUI_10.1.22_01-Dec-25_19-17-25.png  238 kB  Uploaded Tue, 2.12.2025 02:13:29  | Hide | Hide all
CESAR_GUI_10.1.22_01-Dec-25_19-17-25.png
Attachment 7: V1_scan_2025_12_07_23_29_FieldOff.png  511 kB  Uploaded Sun, 7.12.2025 23:29:59  | Hide | Hide all
V1_scan_2025_12_07_23_29_FieldOff.png
Attachment 8: S3_scan_2025_12_07_23_39_FieldOff.png  525 kB  Uploaded Sun, 7.12.2025 23:39:22  | Hide | Hide all
S3_scan_2025_12_07_23_39_FieldOff.png
Attachment 9: printscreen_284_20251207-235949.png  272 kB  Uploaded Mon, 8.12.2025 00:00:03  | Hide | Hide all
printscreen_284_20251207-235949.png
Attachment 10: V0_Scan_2025_12_08_00_13.png  520 kB  Uploaded Mon, 8.12.2025 00:13:33  | Hide | Hide all
V0_Scan_2025_12_08_00_13.png
ELOG V3.1.3-7933898