This is NA61/SHINE electronic logbook (read-only BACKUP!)

Run summary Shift logbook Run settings Beam logbook BPD logbook DAQ logbook DCS logbook Experts logbook Gas logbook TOF logbook Trigger logbook PSD logbook VD logbook Run coordination Detector Upgrade DRS logbook
  Logbook for beam experts  NA61/SHINE logo
Message ID: 232     Entry time: Tue, 21.11.2017 13:18:11
Author: A. Marcinek 
Subject: Xe at 30 AGeV/c : adjustments 
21.11.2017 about 6:30 AM: After access beam moved by 8mm on BPD1y. Tuned BEND03 222.6 -> 223.3

21.11.2017 13:20:23 AM: Intensity on S1 is too small (85k) -> Opened collimators and changed BEND03 223.3 -> 223.0. This gives S1 about 130k for T2 intensity 54x10^8 (yesterday T2 was 64x10^8?)

24.11.2017 09:53:13 AM: Beam is too high on BPD1y and too high on XWCA.021.387. BEND03 222.4 -> 222.2 This changed BPD1y from 0.22 to -0.10. S2/S1 changed from 80% to 95%
ELOG V3.1.3-7933898